Applications of Protein-Based Capacitive Biosensors

Publication Type:
Conference Proceeding
IEEE ICONN 2006, 2006, pp. 235 - 238
Issue Date:
Full metadata record
Files in This Item:
Filename Description SizeFormat
2009004503OK.pdf1.96 MBAdobe PDF
Three different methods of using protein-based capacitive biosensors for the detection of heavy-metal ions are presented. The metal-binding proteins SmtA, S100A12, MerP and four modified MerPs were immobilised as the biorecognition element on self-assembled monolayer-modified gold electrodes. Capacitance was measured using potential square step or electrical impedance spectroscopy. The protein-metal interaction generated changes in capacitance mainly due to a protein conformational change.