A study on the dry cleaning of aluminium surfaces by low temperature plasma process

Publication Type:
Journal Article
Citation:
Journal of the Korean Industrial and Engineering Chemistry, 2008, 19 (6), pp. 640 - 644
Issue Date:
2008-12-01
Filename Description Size
Thumbnail2008005644OK.pdf458.61 kB
Adobe PDF
Full metadata record
Lubricating oil on aluminium surfaces was cleaned by a low temperature plasma process. Oxygen plasma mixed with argon was used, and process parameters were the mixing ratio of argon in oxygen, discharge power, and negative DC potential. The aluminium surfaces were analyzed with FTIR and EDX after the cleaning. It was found that almost all of the oil was eliminated in 20 min. if the oil was pure. Elimination efficiency was highly dependent on operational conditions of the process. The highest efficiency was obtained when treated at 300 W with oxygen plasma mixed with 30% argon applying negative potential more than -500 V on the aluminium surfaces. However, efficiency higher that 60% cannot be obtained at any condition if the oil contained inorganic materials.
Please use this identifier to cite or link to this item: