Analysis of Transient Overvoltage in 220 kV Saturated Core HTS FCL

DSpace/Manakin Repository

Search OPUS


Advanced Search

Browse

My Account

Show simple item record

dc.contributor.author Xiao, H
dc.contributor.author Qiu, J
dc.contributor.author Wang, S
dc.contributor.author Zhang, Q
dc.contributor.author Gong, W
dc.contributor.author Xin, Y
dc.contributor.author Zhu, J
dc.contributor.author Guo, Y
dc.date.accessioned 2012-10-12T03:33:58Z
dc.date.issued 2011-01
dc.identifier.citation IEEE Transactions On Magnetics, 2011, 47 (10), pp. 2620 - 2623
dc.identifier.issn 0018-9464
dc.identifier.other C1 en_US
dc.identifier.uri http://hdl.handle.net/10453/18363
dc.description.abstract Saturated Core High Temperature Superconducting (HTS) Fault Current Limiter (FCL) is one kind of limiters that can work effectively on short-circuit current limitation. In this paper, an equivalent circuit model depending on ac coil of HTS FCL is built for voltage distribution analysis under transient overvoltage. The equivalent circuit components, such as the capacitances and inductances, are calculated by using ?nite element method. The voltage distribution and oscillation analysis of ac coil may bene?t to the insulation design of HTS FCL.
dc.publisher IEEE
dc.relation.hasversion Accepted manuscript version
dc.relation.isbasedon 10.1109/TMAG.2011.2158575
dc.title Analysis of Transient Overvoltage in 220 kV Saturated Core HTS FCL
dc.type Journal Article
dc.parent IEEE Transactions On Magnetics
dc.journal.volume 10
dc.journal.volume 47
dc.journal.number 10 en_US
dc.publocation USA en_US
dc.identifier.startpage 2620 en_US
dc.identifier.endpage 2623 en_US
dc.cauo.name FEIT.School of Elec, Mech and Mechatronic Systems en_US
dc.conference Verified OK en_US
dc.for 0906 Electrical and Electronic Engineering
dc.for 0903 Biomedical Engineering
dc.personcode 910870
dc.personcode 990817
dc.personcode 102910
dc.percentage 50 en_US
dc.classification.name Biomedical Engineering en_US
dc.classification.type FOR-08 en_US
dc.edition en_US
dc.custom en_US
dc.date.activity en_US
dc.location.activity en_US
dc.description.keywords High Temperature Superconducting Fault Current Limiter (HTS FCL), lightning impulse voltage, transient overvoltage. en_US
dc.description.keywords crustaceans, review, toxicology, pollutants, sensitivity, tolerance, zooplankton
dc.description.keywords High Temperature Superconducting Fault Current Limiter (HTS FCL), lightning impulse voltage, transient overvoltage.
pubs.embargo.period Not known
pubs.organisational-group /University of Technology Sydney
pubs.organisational-group /University of Technology Sydney/Faculty of Engineering and Information Technology
pubs.organisational-group /University of Technology Sydney/Faculty of Engineering and Information Technology/School of Elec, Mech and Mechatronic Systems
utslib.copyright.status Open Access
utslib.copyright.date 2015-04-15 12:23:47.074767+10
utslib.collection.history General (ID: 2)


Files in this item

This item appears in the following Collection(s)

Show simple item record