Design of protection circuit for arc welding power supply
- Publication Type:
- Conference Proceeding
- Citation:
- 2011 International Conference on Applied Superconductivity and Electromagnetic Devices, ASEMD 2011, 2011, pp. 232 - 234
- Issue Date:
- 2011-12-01
Closed Access
Filename | Description | Size | |||
---|---|---|---|---|---|
2011001645OK.pdf | Published version | 215.68 kB |
Copyright Clearance Process
- Recently Added
- In Progress
- Closed Access
This item is closed access and not available.
The paper discusses the design of protection circuits responsible for the reliability of arc welding power supply. The protection circuits include three parts, and they are soft-start circuit for anti-surge, circuit for eliminating transformer DC bias magnetic field and circuit for transient over-voltage suppression, respectively. The detail calculations about component parameters of these circuits are given. The transformer and the power devices in this paper are regarded as ideal devices. Meanwhile, their losses are neglected. The method can provide certain guide for improving reliability of protection circuit. © 2011 IEEE.