Calculation of Radial Forces in Cage Induction Motors at Start - The Effect of Rotor Differential

Publisher:
IEEE
Publication Type:
Journal Article
Citation:
IEEE Transactions On Magnetics, 2010, 46 (8), pp. 3029 - 3032
Issue Date:
2010-01
Full metadata record
Files in This Item:
Filename Description Size
Thumbnail2009007567OK.pdf743.26 kB
Adobe PDF
In this paper, the radial forces in an induction motor are calculated using finite element analysis. These radial forces (or unbalanced magnetic pull-UMP) are generated when the rotor is eccentric. The work illustrates the importance of higher winding harmonics and rotor differential leakage in the starting UMP. Examples of a 6 pole machine with 26 and 40 bar rotors show that increasing the bar number and air-gap length will reduce the UMP. Further studies are carried out using parameter variation and a 10-pole machine is also addressed, where experimental results exist, in order to validate the calculation.