Wear characteristics of patterned and un-patterned tetrahedral amorphous carbon film in the presence of synthetic and bio based lubricants

Publisher:
IOP PUBLISHING LTD
Publication Type:
Journal Article
Citation:
Materials Research Express, 2019, 6, (3)
Issue Date:
2019-03-01
Filename Description Size
Arslan_2019_Mater._Res._Express_6_036414.pdfPublished version1.08 MB
Adobe PDF
Full metadata record
In this article, wear performance of patterned and non-patterned tetrahedral carbon thin film (ta-C) is compared in the presence of various lubricants. For this purpose, wear tests were conducted at temperatures (40 °C-125 °C) which are normally found during automotive engine operation. Wear test were conducted at 100 N load and 120 min. The results showed that bio-based lubricant show better wear performance at 40 and 80 °C compared to PAO lubricant for both laser patterned and non-patterned ta-C thin film. However, at the temperature of 125 °C, PAO showed better wear performance than palm based TMP ester. This can be because of unstable film formation at higher temperatures in case of bio-based lubricant. It was also found that patterned ta-C thin films shows higher wear resistance than non-patterned thin film. This can be because of micro pores which can provide lubricant, capture micro and nano wear particle and behave as micro hydrodynamic bearings.
Please use this identifier to cite or link to this item: