Impact response of ultra-high performance fiber-reinforced concrete filled square double-skin steel tubular columns
- Publication Type:
- Journal Article
- Citation:
- Steel and Composite Structures, 2022, 42, (3), pp. 325-351
- Issue Date:
- 2022-02-01
Closed Access
Filename | Description | Size | |||
---|---|---|---|---|---|
4_325_351_SCS11207C_edited.pdf | Published version | 5.03 MB |
Copyright Clearance Process
- Recently Added
- In Progress
- Closed Access
This item is closed access and not available.
This paper studies the lateral impact behavior of ultra-high performance fiber-reinforced concrete (UHPFRC) filled double-skin steel tubular (UHPFRCFDST) columns. The impact force, midspan deflection, and strain histories were recorded. Based on the test results, the influences of drop height, axial load, concrete type, and steel tube wall thickness on the impact resistance of UHPFRCFDST members were analyzed. LS-DYNA software was used to establish a finite element (FE) model of UHPFRC filled steel tubular members. The failure modes and histories of impact force and midspan deflection of specimens were obtained. The simulation results were compared to the test results, which demonstrated the accuracy of the finite element analysis (FEA) model. Finally, the effects of the steel tube thickness, impact energy, type of concrete and impact indenter shape, and void ratio on the lateral impact performances of the UHPFRCFDST columns were analyzed.
Please use this identifier to cite or link to this item: