Thermal analysis of duplex three-phase induction motor under fault operating conditions

Publication Type:
Journal Article
Citation:
IEEE Transactions on Industry Applications, 2013, 49 (4), pp. 1523 - 1530
Issue Date:
2013-08-05
Filename Description Size
Thumbnail2013001081OK.pdf1.8 MB
Adobe PDF
Full metadata record
This paper describes a thermal model for a duplex three-phase induction machine for fault-tolerant applications. The three- and six-phase variations of the duplex three-phase machine operation under fault conditions are considered. Different winding configurations are investigated. Thermal analysis is performed using analytical and finite-element models. An experimental validation is presented for load operating conditions. © 1972-2012 IEEE.