Source identification and separation using sub-band ICA of sEMG

Publication Type:
Conference Proceeding
Citation:
IEEE Region 10 Annual International Conference, Proceedings/TENCON, 2008
Issue Date:
2008-12-01
Filename Description Size
2012007320OK.pdf Published version349.75 kB
Adobe PDF
Full metadata record
Source identification and separation of number of active muscles during a complex action is useful information to identify the action, and to determine pathologies. Biosignals such as surface electromyogram are a result of the summation of electrical activity of a number of sources. The complexity of the anatomy and actions results difficulty in identifying the number of active sources from the multiple channel recordings. ICA has been applied to sEMG to separate the signals originating from different sources. But it is often difficult to determine the number of active sources that may vary between different actions and gestures. This paper reports research conducted to evaluate the use of sub-band ICA for the separation of bioelectric signals when the number of active sources may not be known. The paper proposes the use of value of the determinant of the global matrix generated using sub-band ICA for identifying the number of active sources. The results indicate that the technique is successful in identifying the number of active muscles for complex hand gestures.
Please use this identifier to cite or link to this item: