Plasma-Lyte 148 vs 0.9% saline for fluid resuscitation in diabetic ketoacidosis

Publication Type:
Journal Article
Citation:
Journal of Critical Care, 2012, 27 (2), pp. 138 - 145
Issue Date:
2012-04-01
Filename Description Size
1-s2.0-S0883944112000202-main.pdfPublished Version321.22 kB
Adobe PDF
Full metadata record
Purpose: The purpose of the study was to determine the effects of Plasma-Lyte 148 (PL) vs 0.9% saline (NS) fluid resuscitation in diabetic ketoacidosis (DKA). Methods: A multicenter retrospective analysis of adults admitted for DKA to the intensive care unit, who received almost exclusively PL or NS infusion up until 12 hours, was performed. Results: Nine patients with PL and 14 patients with NS were studied. Median serum bicarbonate correction was higher in the PL vs NS groups at 4 to 6 hours (8.4 vs 1.7 mEq/L) and 6 to 12 hours (12.8 vs 6.2 mEq/L) from baseline (P < .05). Median standard base excess improved by 10.5 vs 4.2 mEq/L at 4 to 6 hours and by 16.0 vs 9.1 mEq/L at 6 to 12 hours in the PL and NS groups, respectively (P < .05). Chloride levels increased significantly in the NS vs PL groups over 24 hours. Potassium levels were lower at 6 to 12 hours in the PL group. Mean arterial blood pressure was higher at 2 to 4 hours in the PL group, whereas cumulative urine output was lower at 4 to 6 hours in the NS group. There were no differences in glycemic control or duration of intensive care unit stay. Conclusion: Patients with DKA resuscitated with PL instead of NS had faster initial resolution of metabolic acidosis and less hyperchloremia, with a transiently improved blood pressure profile and urine output. © 2012 Elsevier Inc.
Please use this identifier to cite or link to this item: