The accuracy and precision of the KIM motion monitoring system used in the multi-institutional TROG 15.01 Stereotactic Prostate Ablative Radiotherapy with KIM (SPARK) trial
Hewson, EA
Nguyen, DT
O’Brien, R
Kim, JH
Montanaro, T
Moodie, T
Greer, PB
Hardcastle, N
Eade, T
Kneebone, A
Hruby, G
Hayden, AJ
Turner, S
Siva, S
Tai, KH
Hunter, P
Sams, J
Poulsen, PR
Booth, JT
Martin, J
Keall, PJ
- Publication Type:
- Journal Article
- Citation:
- Medical Physics, 2019, 46 (11), pp. 4725 - 4737
- Issue Date:
- 2019-11-01
Closed Access
Filename | Description | Size | |||
---|---|---|---|---|---|
mp.13784.pdf | Published Version | 3.32 MB | Adobe PDF |
Copyright Clearance Process
- Recently Added
- In Progress
- Closed Access
This item is closed access and not available.
Full metadata record
Field | Value | Language |
---|---|---|
dc.contributor.author | Hewson, EA | en_US |
dc.contributor.author |
Nguyen, DT https://orcid.org/0000-0003-1581-0359 |
en_US |
dc.contributor.author | O’Brien, R | en_US |
dc.contributor.author | Kim, JH | en_US |
dc.contributor.author | Montanaro, T | en_US |
dc.contributor.author | Moodie, T | en_US |
dc.contributor.author | Greer, PB | en_US |
dc.contributor.author | Hardcastle, N | en_US |
dc.contributor.author | Eade, T | en_US |
dc.contributor.author | Kneebone, A | en_US |
dc.contributor.author | Hruby, G | en_US |
dc.contributor.author | Hayden, AJ | en_US |
dc.contributor.author | Turner, S | en_US |
dc.contributor.author | Siva, S | en_US |
dc.contributor.author | Tai, KH | en_US |
dc.contributor.author | Hunter, P | en_US |
dc.contributor.author | Sams, J | en_US |
dc.contributor.author | Poulsen, PR | en_US |
dc.contributor.author | Booth, JT | en_US |
dc.contributor.author | Martin, J | en_US |
dc.contributor.author | Keall, PJ | en_US |
dc.date.accessioned | 2020-04-03T03:40:59Z | |
dc.date.available | 2019-08-16 | en_US |
dc.date.available | 2020-04-03T03:40:59Z | |
dc.date.issued | 2019-11-01 | en_US |
dc.identifier.citation | Medical Physics, 2019, 46 (11), pp. 4725 - 4737 | en_US |
dc.identifier.issn | 0094-2405 | en_US |
dc.identifier.uri | http://hdl.handle.net/10453/139766 | |
dc.description.abstract | © 2019 American Association of Physicists in Medicine Purpose: Kilovoltage intrafraction monitoring (KIM) allows for real-time image guidance for tracking tumor motion in six-degrees-of-freedom (6DoF) on a standard linear accelerator. This study assessed the geometric accuracy and precision of KIM used to guide patient treatments in the TROG 15.01 multi-institutional Stereotactic Prostate Ablative Radiotherapy with KIM trial and investigated factors affecting accuracy and precision. Methods: Fractions from 44 patients with prostate cancer treated using KIM-guided SBRT were analyzed across four institutions, on two different linear accelerator models and two different beam models (6 MV and 10 MV FFF). The geometric accuracy and precision of KIM was assessed from over 33 000 images (translation) and over 9000 images (rotation) by comparing the real-time measured motion to retrospective kV/MV triangulation. Factors potentially affecting accuracy, including contrast-to-noise ratio (CNR) of kV images and incorrect marker segmentation, were also investigated. Results: The geometric accuracy and precision did not depend on treatment institution, beam model or motion magnitude, but was correlated with gantry angle. The centroid geometric accuracy and precision of the KIM system for SABR prostate treatments was 0.0 ± 0.5, 0.0 ± 0.4 and 0.1 ± 0.3 mm for translation, and −0.1 ± 0.6°, −0.1 ± 1.4° and −0.1 ± 1.0° for rotation in the AP, LR and SI directions respectively. Centroid geometric error exceeded 2 mm for 0.05% of this dataset. No significant relationship was found between large geometric error and CNR or marker segmentation correlation. Conclusions: This study demonstrated the ability of KIM to locate the prostate with accuracy below other uncertainties in radiotherapy treatments, and the feasibility for KIM to be implemented across multiple institutions. | en_US |
dc.relation.ispartof | Medical Physics | en_US |
dc.relation.isbasedon | 10.1002/mp.13784 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.subject.classification | Nuclear Medicine & Medical Imaging | en_US |
dc.subject.mesh | Humans | en_US |
dc.subject.mesh | Prostatic Neoplasms | en_US |
dc.subject.mesh | Radiosurgery | en_US |
dc.subject.mesh | Radiotherapy Planning, Computer-Assisted | en_US |
dc.subject.mesh | Retrospective Studies | en_US |
dc.subject.mesh | Particle Accelerators | en_US |
dc.subject.mesh | Male | en_US |
dc.subject.mesh | Radiotherapy, Image-Guided | en_US |
dc.subject.mesh | Dose Fractionation, Radiation | en_US |
dc.title | The accuracy and precision of the KIM motion monitoring system used in the multi-institutional TROG 15.01 Stereotactic Prostate Ablative Radiotherapy with KIM (SPARK) trial | en_US |
dc.type | Journal Article | |
utslib.citation.volume | 11 | en_US |
utslib.citation.volume | 46 | en_US |
utslib.for | 0299 Other Physical Sciences | en_US |
utslib.for | 0903 Biomedical Engineering | en_US |
utslib.for | 1112 Oncology and Carcinogenesis | en_US |
pubs.embargo.period | Not known | en_US |
pubs.organisational-group | /University of Technology Sydney | |
pubs.organisational-group | /University of Technology Sydney/Faculty of Engineering and Information Technology | |
pubs.organisational-group | /University of Technology Sydney/Faculty of Engineering and Information Technology/School of Biomedical Engineering | |
pubs.organisational-group | /University of Technology Sydney/Strength - CHT - Health Technologies | |
utslib.copyright.status | closed_access | * |
pubs.issue | 11 | en_US |
pubs.publication-status | Published | en_US |
pubs.volume | 46 | en_US |
Abstract:
© 2019 American Association of Physicists in Medicine Purpose: Kilovoltage intrafraction monitoring (KIM) allows for real-time image guidance for tracking tumor motion in six-degrees-of-freedom (6DoF) on a standard linear accelerator. This study assessed the geometric accuracy and precision of KIM used to guide patient treatments in the TROG 15.01 multi-institutional Stereotactic Prostate Ablative Radiotherapy with KIM trial and investigated factors affecting accuracy and precision. Methods: Fractions from 44 patients with prostate cancer treated using KIM-guided SBRT were analyzed across four institutions, on two different linear accelerator models and two different beam models (6 MV and 10 MV FFF). The geometric accuracy and precision of KIM was assessed from over 33 000 images (translation) and over 9000 images (rotation) by comparing the real-time measured motion to retrospective kV/MV triangulation. Factors potentially affecting accuracy, including contrast-to-noise ratio (CNR) of kV images and incorrect marker segmentation, were also investigated. Results: The geometric accuracy and precision did not depend on treatment institution, beam model or motion magnitude, but was correlated with gantry angle. The centroid geometric accuracy and precision of the KIM system for SABR prostate treatments was 0.0 ± 0.5, 0.0 ± 0.4 and 0.1 ± 0.3 mm for translation, and −0.1 ± 0.6°, −0.1 ± 1.4° and −0.1 ± 1.0° for rotation in the AP, LR and SI directions respectively. Centroid geometric error exceeded 2 mm for 0.05% of this dataset. No significant relationship was found between large geometric error and CNR or marker segmentation correlation. Conclusions: This study demonstrated the ability of KIM to locate the prostate with accuracy below other uncertainties in radiotherapy treatments, and the feasibility for KIM to be implemented across multiple institutions.
Please use this identifier to cite or link to this item:
Download statistics for the last 12 months
Not enough data to produce graph