Investigating the reliability of contemporary Chinese pulse diagnosis as a diagnostic tool in Oriental medicine
- Publication Type:
- Thesis
- Issue Date:
- 2012
Open Access
Copyright Clearance Process
- Recently Added
- In Progress
- Open Access
This item is open access.
Introduction: Few studies have evaluated the reliability of pulse diagnosis clinically despite it
being a fundamental part of Oriental medicine diagnostics. The objective of this
study was to determine the levels of intra-rater and inter-rater reliability of
practitioners using an operationally defined method, Contemporary Chinese Pulse
Diagnosis™ (CCPD), to evaluate the radial pulse of volunteer subjects.
Methods:
The study utilised a real-life design to investigate CCPD in a clincal setting. Fifteen
volunteer subjects and six testers skilled in the CCPD method were recruited. Two
episodes of data collection were conducted 28 days apart as a practical test and
retest. For each subject, four pulse rates and 30 pulse categories defined nby the CCPD
system were assessed and reassessed by the same four testers during both phases of
testing. All assessments were conducted according to the CCPD method.
Intra rater reliability was measured by comparing individual tester results on day
one with day two, while inter rater agreement and reliability were determined by
comparing all testers across both days. Rates were analysed using ANOVA, while the
remaining data employed Cohen's kappa coefficient. Kappa values were interpreted
according to previous clinical studies and parameters considered acceptable when
using a tool such as CCPD to assist in clinical diagnosis. Cross-referencing percentage
agreement with the appropriate kappa results rated individual pulse quality
dependability.
Results:
Of the 11760 kappa calculations excellent to good agreement (kappa =0.60) in 67%
of intra rater and 44.1% of inter rater calculations indicated CCPD to be a reliable
method of pulse diagnosis. Unacceptable agreement (kappa =0.40) in 14.3% of intra
rater and 30.5% of inter rater calcualtions correlated most profoundly to CCPD
pulse category/position and to several subjects. Reliability of individual pulse
qualities depended on the location of the quality, the complexity of the sensation
description and the classification of grouping to which the quality belonged.
Conclusions:
The results confirmed the findings of earlier studies that when the system of pulse
diagnosis is operationally defined, acceptable levels of reliabilitycan be achieved.
Additionally bilateral methods of palpation were identified as more reliable than
those that assessed pulse positions using a single finger.
Unacceptable reliability for the Combined Complementary Positions suggested
imprecise descriptions, wording or language for accessing the Pleura, Esophagus and
Diaphragm Positions may exist within the CCPD operational definitions. Further any
uncertain terminology needs revision as the data indicated this might have
contributed to variance within the testers' techniques. Also the pulse qualities
Muffled, Change of Amplitude, Blood Heat, Blood Thick, and Flooding Deficient,
while not shown to be unreliable, had comparatively lower reliability suggesting the
definitions for these qualities may also need modification. If variance continues
following review, then the reliability within a clinical context of these positions and
qualities needs to be re-evaluated entirely.
Please use this identifier to cite or link to this item:
